Testing CSU

Access Manager 2000 User Manual

8-53

You will activate the CSU loopback that is required for this test. For
example, when sending a test signal toward the NET (network), an RLB
is first activated at the near-end NCC or TAC. An LLB or PLB can be
activated at the far end. As another example, when a test signal is sent
toward the EQPT (equipment), a PLB is first activated at the near end.

This T1 test signal application is shown in the figure below

Figure 8-2

Applying a T1 test signal

To test an AS2000 CSU

1. When you get the On-line Access sub-menu, select the

Select

Test

option. The Specify Circuit Element to Receive Test Request

screen appears.

2. Enter the shelf in which the desired NCC or TAC is located. This

number can be from 1 to 4 in each Access System 2000 node or

Test toward equipment

Eqpt

Repeater

Near-end NCC or TAC

Far-end NCC or TAC

NCC or TAC

LLB

PLB

RLB

PLB

DET

GEN

DET

GEN

Eqpt

Eqpt

Network

Network

Test toward net

GEN = Test Signal Generator

DET = Error Detector / Counter