Configuring the T1 Network

5-28

Access Manager 2000 User Manual

The

Use

field is used to assign a relative priority to an alarm path. To

view the available options, go to the

Use

field and press

. A pop up

menu will appear with these options:

SEND

The alarm will be reported to this alarm path.

BACKUP

The alarm will be sent to this path if the SEND path is
unable to deliver the alarm.

NONE

Alarms are not to be sent to this path.

The acceptable combinations of options for this field are listed below:

Based on the relative priorities you want to assign, enter your choices in
the

Primary

and

Secondary

columns.

Setting up alarm destination access

To set up alternate alarm paths, you’ll be using either a modem, a stat
mux, or an X.25 PAD to communicate with Access Manager.

You need to specify the:

type of device connected to the node controller

speed at which the device operates

address of the alarm destination

You must use the same com port access device and baud rate for both
alarm paths.

Primary

Secondary

Description

SEND

SEND

Send to both addresses specified

SEND

BACKUP

Send to Secondary address only if Primary address is unavailable

BACKUP

SEND

Send to Primary address only if Secondary address is unavailable

SEND

NONE

Send only to the Primary address

NONE

SEND

Send only to the Secondary address

NONE

NONE

Do not send any alarms to either address