Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual

Page 243

Advertising
background image

Deactivating alarms

Access Manager 2000 User Manual

6

-5

To deactivate alarm records by date and time:

1. Starting from the Main Menu, select

Alarm Status

. The Alarm

Status (Review Alarm Log Database) screen now appears.

2. From

this

screen,

select

Deactivate

. The Deactivate (Select

Alarm to Deactivate) screen now appears. Follow these steps to
select a date and time range through which alarm records are
deactivated.

3. Press

. The Enter Date/Time Range for Alarm Deactivation

screen appears.

The date and time range is displayed from the oldest alarm record in
the database to the current time. Change the date and time to the
range you want to deactivate.

4. To select all the alarms within the range entered, press the

key. Or, press

to abort.

5. To deactivate the alarm reports in the selected range, press

.

Or, press

to abort deactivation.

6. If you pressed

, a prompt appears, asking you to confirm that

you want to deactivate the selected alarms. To deactivate the alarms,
type

Y

. Pressing any other key cancels deactivation of the selected

alarms.

Note:

The alarm records selected by date and time are not shown on the
screen as they were in the preceding Tagging Alarm Records for
Deactivation section.

Selecting Alarm
Records by Date
and Time for
Deactivation

F8

F5

F2

Enter

F2

Enter

Advertising