Installing Access Manager

2-14

Access Manager 2000 User Manual

Physical connections between the host PC and xxx.

Your host PC must be running pcANYWHERE.

You must be using the largest (-1000) Access Manager package.

You must use the Access Manager menus to set up a utility.

Your

AUTOEXEC.BAT

file must include the time zone variable,

TZ = xSTn. This must always accurately reflect the appropriate
standard time or daylight savings time.

Time Zone Setup for Accumaster

Since the alarms sent to Accumaster must be time-stamped and include
time zone, an environment variable (TZ) must be set up in your

AUTOEXEC.BAT

file.

The following line should be added to the

AUTOEXEC.BAT

file prior to

any batch command that automatically starts Access Manager.

SET = xSTn

where x and n are filled in from Figur e2-3, Accumaster Time Zone
Chart”. F
or example, EST5 would be used in the Eastern Time Zone
when daylight savings time is not in effect.

Table 2-3

Accumaster Time Zone Chart

The time zone string (for example, PST) is not critical, as long as it is
three characters long. The number following the string is critical because
it represents the number of hours difference from Greenwich Mean Time
(GMT), which must be included in all alarm records sent to Accumaster.

Time Zone

Standard Time

When/If Daylight Saving

Time is in Effect

Hawaii

HST10

HST9

Alaska

LST9

LST8

Pacific

PST8

PST7

Mountain

MST7

MST6

Central

CST6

CST5

Eastern

EST5

EST4

Atlantic

AST4

AST3