Configuring the T1 Network

5-88

Access Manager 2000 User Manual

This option functions like

Signal to EQP on LOS

option

described below, except the trigger condition is LOF. See warning in that
section. The default is

YES

.

If this option is set to

YES

, then whatever signal is received from the

network is sent to the equipment.

If this option is set to

NO

, then AIS is sent to the equipment until the LOS

alarm clears. The default is

YES

(signal).

CAUTION

Setting this option to

NO

causes an out-of-service condition during

LOS from the network, starting when the condition is detected and
lasting as long as the condition persists plus from 0 seconds to 255
seconds (depending on the user-selected alarm delay time). The
default is 10 seconds.

This option is functionally similar to the EQP

Receive Jitter

Buffer = 40 Bits

option, except that the buffer in this option is for

the incoming signal from the network. The default setting is

YES

.

When set to

YES

(the default), the ESF Data Link idle code is ALL-

ONEs. When this option is set to

NO

, the Data Link idle code is Flags.

Set this option to

YES

(default) to allow the CSU to automatically

perform a self-test each time it is powered up.

Set this option to

YES

(default setting) if you want the CSU to respond to

loopback commands sent to it either on the ESF Data Link or directly
from Access Manager.

Signal to EQP on
NET LOF

Signal to EQP on
NET LOS

!

NET RCV Jitte
BUF = 40 Bits

Data Link Idle
Code (Idle code) =
Flags

Power-up Near End
Self Test

Loopback Enable

Advertising