Enable remote configuration, Ber threshold – Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual

Page 188

Advertising
background image

Configuring the T1 Network

5-64

Access Manager 2000 User Manual

This option must be set to

YES

and the

Installed and

Operational

option must also be set to

YES

to enable Access

Manager to configure the selected CSU circuit elements.

In the following figures, the options following

Enable Remote

Configuration

are downloaded to the CSU circuit element when

is pressed. View the appropriate figure (for your equipment) from

the list below:

If this option is set to

NO

, any changes made are only saved in the

database but are not downloaded to the CSU circuit element. Remote
configuration refers to the fact that these options are downloaded from the
Access Manager database.

Note:

You should set the

Enable Remote Configuration

option to

YES

only during the time that the actual remote

configuration is being performed. This is to avoid performing a
remote configuration (if this option is set to

YES

) each time you

edit a circuit element just to change the data to be collected.

This option sets the bit error rate (BER) threshold on the network side to a
rate from 10

-4

to 10

-9

, with a default value of 10

-6

.

A value of

ZERO

disables the BER alarm function.

The approximate length of time for automatic alarm to reset may vary
according to which BER threshold you select, as shown in the following
two tables.

Table 5-8, “Older CSU Circuit Elements BER Alarm Rest Times

Table 5-9, “Newer CSU Circuit Elements BER Alarm Reset Times

Enable Remote
Configuration

F5

BER Threshold