Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual

Page 157

Advertising
background image

Configuring nodes

Access Manager 2000 User Manual

5

-33

Error messages

If you’ve made an error in selecting your alarm path parameters, one of the following
error message will appear on your screen.

Error Message

Cause

Corrective Action

Invalid USE on Primary
Path

You selected a

Use

type other

than

NONE

,

SEN

, or

BACKU

.

Go to the

Use

field and verify that each

alarm path has a value of eithe

NONE

,

SEN

, or

BACKU

.

Invalid USE on
Secondary Path

Invalid Device
specified on Primary
Path

You selected a

Device Type

other than

DIREC

,

MODEM

,

STAT-MUX

, or

X.25 PA

.

Go to the

Device Type

field and verify that

each alarm path has a value of eithe

DIREC

,

MODEM

,

STAT-MUX

, or

X.25 PA

.

Invalid Device
specified on Secondary
Path

At least one SEND path
must be specified

A

BACKUP

path has been

selected with no existing

SEND

path.

If you want to use a backup path, go to the

Use

field and see which alarm path you’ve

labeled

BACKU

. Change the other alarm

path’s

Use

field to

SEN

.

Primary and Auxiliary
device types must be
the same

Two different device types were
selected.

Go to the

Device Type

field and verify that

both alarm paths are either

MODEM

,

STAT-MUX

, or

X.25 PA

.

Time format must be 1-
59 SEC, 1-59 MIN, 1-24
HR

• The

Retry Interval

is not

in the proper format, or

• The

Wait Interval

is not in

the proper format.

Go to the

Retry Interval

and

Wait

Interval

fields. Verify the following:

• The time unit is abbreviated correctly.

• The number is appropriate to the time

unit. (For example, you haven’t entered

27 HRS

.)

BACKUP unreachable
because SEND set for
continuous

A

BACKUP

path is specified while

the

SEND

path set for continuous

(attempts = 0). In other words, if
the

SEND

path is set to 0, it never

gives up, and a

BACKUP

path is

irrelevant.

Either:

• Set the

SEND

path for 1 to 256 attempts,

or

• Change the alarm path

Use

field from

BACKUP

to

NONE

.

X.25 PAD supported only
by AS2000 equipment

User specified X.25 PAD for use
with non-AS2000 equipment

Check you

Alarm path

and

Query Path

setups to see which of the following
connections you’re using: direct, modem, or
stat mux. Then change the entry in the

Device Type

field to reflect that.