Configuring the T1 Network

5-76

Access Manager 2000 User Manual

Figure 5-14 Typical

NCC or TAC configuration option menu

These options are described in the following sections.

This option determines whether the circuit element is installed and
operational. This option, marked with an asterisk (*), must be set to

YES

in order to enable any of the following options, including collection of
performance monitoring data, alarm reporting, etc.

You must set the

Installed and Operational

option for the

circuit element’s parent node to

YES

before Access Manager will allow

you to set this option to

YES

for the circuit element. The default setting

is

NO

.

These options enable or disable an NCC, CCC, or TAC collection of near-
end or far-end performance data.

If you select

YES

for either option, also press

and then select the

network and/or EQP data registers to be retrieved. The register types are
NET User, NET Additional, and EQP.

The near-end defaults are

NET User=YES

,

NET Additional=NO

,

and

EQP=NO

. All far-end defaults are

NO

.

Installed and
Operational

Retrieve Near-En
Performance Data /
Retrieve Far-En
Data