Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual

Page 158

Advertising
background image

Configuring the T1 Network

5-34

Access Manager 2000 User Manual

For each Access System 2000 or ConnecT1 plus node:

To allow a local operator to use the thumbwheel switches on the
master NCC 2020 or CCC 1020 for CSU access, configuration, and/
or testing, select

YES

(default setting).

To prevent unauthorized use of these switches, select

NO

. This

setting disables the thumbwheel switches.

Until this release of Access Manager, the node clock in the NCC2020
(and NCC 1020) would be set from the PC running Access Manager
whenever:

you configured a node

Access Manager polled the node controller for performance data.

Now you can choose whether or not you want the clock set in either or
both of these conditions.

This is especially helpful whenever two Access Managers, in different
time zones, communicate with the same node. In such an instance, you’d
probably want to give only one Access Manager the power to set the
clock.

The two parameters which deal with this in the Node Definition menu are:

Set Node Clock When Configuring . . ? N

Set Node Clock When Polling . . . . ? N

Entering a

Y

will enable the feature. Entering an

N

will disable it.

Retry Interval must be
the same if SEND/SEND
specified

Although you have specified

SEND

for both alarm paths, you

have specified different

Retry

Intervals

.

Make both

Retry Intervals

the same.

Attempts must be
limited to 15 or less
when MODEM is selected

The

Device Type

is

MODEM

and

the

Attempts

are greater than

15.

For

Attempt

, select a value from 1 to 15.

Error Message

Cause

Corrective Action

Enabling
thumbwheel
operation

Resetting the node
clock