Displaying individual circuit element status

Access Manager 2000 User Manual

8-23

In the following screen, the status indicators show the source of timing
for the TIU .

If both the

EXT TTL

and

EXT 422

lines on the screen are

NO

and the

Frequency

line indicates

Nx56kbps

or

Nx64kbps

,

then the TIU is timing off the data bus from a DIU.

If either the

EXT TTL

or

EXT 422

line is

YES

on the screen

and

Frequency

line is

Nx56kbps

or

Nx64kbps

, then the

TIU is timing off a data port.

The following items explain the fields in this screen.

Field Value

Meaning

Frequency

The frequency of the clock source from which
the TIU derives synchronization.

EQPT Clock

Yes

The source clock is in the signal received fro
the EQPT.

NET Clock

Yes

The source clock is in the signal received fro
the NET.

DIU

Yes

The source clock is derived internally, from the
DIU

EXT-TTL

Yes

The source clock is from an external source,
not EQPT or NET signal, at TTL levels.

EXT-442

Yes

The source clock is from an external source,
not EQPT or NET signal, at RS422 levels.