Displaying telco and user data – Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual

Page 298

Advertising
background image

Monitoring and Troubleshooting Access Manager

8-28

Access Manager 2000 User Manual

3. After viewing the configuration screen, press

to return to the

On-line Access Menu.

Displaying Telco and User data

For any Verilink CSU, you can review Telco and user data from
performance registers. These on-line registers are located in the CSU
element.

For all Verilink CSUs, this information is available in breakdowns of 1
hour and 24 hours.

You can also view this information in three different forms. These include
performance data registers, statistics, and barcharts.

Performance data registers provide you with raw data, displayed by
type of error and time interval.

Statistics take that raw data and present it to you in terms of
percentages.

Barcharts provide a visual representation of the performance data.

Up to four types of register sets are available for Verilink equipment: one
for equipment parameters and three for network parameters.

Verilink CSUs have register sets for User performance data and Telco
data. Older equipment has fewer registers than newer equipment. AS2000
CSUs also provide register sets for equipment data and additional
(Verilink-defined) user data for more comprehensive network monitoring.
These register sets are summarized in Table 8-1, “Types of performance
registers”
.

Only the Telco register set cannot be reset by the user.

If a given register is not supported by the equipment, then the data register
column will sho

N/A

for “not available” when you use the On-line

Menu to access the data summaries.

F2

Advertising