Configuration Options for AS2000 and ConnecT1 Plus

Access Manager 2000 User Manual

5

-79

The NET BER threshold is the maximum bit error rate allowed for
signals coming from the network. The EQP BER threshold is the
maximum bit error rate allowed for signals coming from the
network. Each can be set to any value between 10

-4

and 10

-9

. The

default is to 10

-6

.

Go to the

EQP BER threshold

field , and enter the positiv

value of the exponent. For example, for a bit error rate of 10

-5

,

enter

5

. Remember, the higher the exponent, the lower the

threshold. Do the same with the

NET BER threshold

field.

The default value is

6

, for 10

-6

.

To disable the alarm, select

0

(zero).

2.

Set alarm thresholds and interval counts

for each of these three

types of trouble seconds:

Errored Seconds-Line - ES-L; that is, the number of seconds
with bipolar violations, indicating formatting errors. This refers
only to BPVs which are not an intentional part of B8ZS line
coding.

Errored Seconds - ES; that is, the number of seconds with
CRC-6 errors, indicating a violation of data integrity

Unavailable Seconds - UAS, that is, any second during which a
UASS (Unavailable Signal State) exists

First, an explanation of thresholds and interval counts.

Y

trouble second

definitions

Advertising