Guardian Co-Deposition Controller Operating Manual

3.8.5 Comm Tab

The Comm Tab sets up communications between the EIES program and the
Guardian controller. Settings are made in two panels, Guardian and External.

Figure 3-27 Edit System Comm Tab

3.8.5.1 Guardian

Comm Port: . . . . . . . . . . . . . . . . . . Disabled, Com 1 to 9, Ethernet

Selects a computer RS-232 serial port or Ethernet port for communicating with the
Guardian controller. If a comm port is not installed, or is being used by another
program, an error message will be displayed, otherwise, the Version # for the
controller firmware is shown.

If Ethernet is selected as the Comm Port, Port and IP Address selection fields will
appear:

Ethernet Port: Shows the current IP port and allows changing it. Default
Ethernet Port is 2101.

IP Address: Displays the current IP address and allows changing it. The
default Guardian IP address is 192.168.1.200. For a direct connection, set the
computer’s IP address to be the same as the Guardian’s except the last group
must be different. For example, to communicate with a Guardian at the default
address, set the computer to 192.168.1.100.