From V1.4

Logged status.

Logbook function in the SM301

Value is bit-coded:

Info

Bit 0 STO via SD-In

STO was triggered via a safe input.

Bit 1 STO via S-bus

STO was triggered via the safety bus.

Bit 2 STO by error

STO was triggered by an error.

Bit 3 Reserved
Bit 4 SS1 via SD-In

SS1 was triggered via a safe input.

Bit 5 SS1 via S-bus

SS1 was triggered via the safety bus.

Bit 6 SS1 by error

SS1 was triggered by an error.

Bit 7 Reserved
Bit 8 SS2 via SD-In

SS2 was triggered via a safe input.

Bit 9 SS2 via S-bus

SS2 was triggered via the safety bus.

Bit 10 SS2 by error

SS2 was triggered by an error.

Bit 11 Reserved
Bit 12 SLS1 via SD-In

SLS1 was triggered via a safe input.

Bit 13 SLS1 via S-bus

SLS1 was triggered via the safety bus.

Bit 14 SLS1 via OMS

SLS1 was triggered via the operating mode changeover.

Bit 15 Reserved
Bit 16 SLS2 via SD-In

SLS2 was triggered via a safe input.

Bit 17 SLS2 via S-bus

SLS2 was triggered via the safety bus.

Bit 18 SLS2 via OMS

SLS2 was triggered via the operating mode changeover.

Bit 19 Reserved
Bit 20 SLS3 via SD-In

SLS3 was triggered via a safe input.

Bit 21 SLS3 via S-bus

SLS3 was triggered via the safety bus.

Bit 22 SLS3 via OMS

SLS3 was triggered via the operating mode changeover.

Bit 23 Reserved
Bit 24 SLS4 via SD-In

SLS4 was triggered via a safe input.

Bit 25 SLS4 via S-bus

SLS4 was triggered via the safety bus.

Bit 26 SLS4 via OMS

SLS4 was triggered via the operating mode changeover.

Bit 27 Reserved
Bit 28 SDIpos via SD-In

SDIpos was triggered via a safe input.

Bit 29 SDIpos via S-bus

SDIpos was triggered via the safety bus.

Bit 30 SDIpos via SLS

SDIpos was triggered in combination with SLS.

Bit 31 SDIpos in normal operation

SDIpos was triggered during normal operation.

Bit 32 SDIneg via SD-In

SDIneg was triggered via a safe input.

Bit 33 SDIneg via S-bus

SDIneg was triggered via the safety bus.

Bit 34 SDIneg via SLS

SDIneg was triggered in combination with SLS.

Bit 35 SDIneg in normal operation

SDIneg was triggered during normal operation.

Bit 36 SLI active

SLI was triggered during special operation.

Bit 37 Reserved
Bit 38 Reserved