Short overview of the "Safe output" parameter group:

SD-Out1 switching condition
Configuration of the switching conditions that are to be assigned to the safe output.

• Several switching conditions can be simultaneously assigned to the safe output.
• For each switching condition it can be individually set whether it is to be evaluated with a

positive or negative logic.

• In order to assign one or several conditions to the safe output, simply change the settings for

these conditions from "Not evaluated" to "Positive logic" or "Negative logic".

• The "SD-Out1" bit of the PROFIsafe output data is included in the evaluation via the selected

logic function. The evaluation for this bit can be deactivated via the parameters "S bus:

Configuration" and "S bus: Filter control data".

SD-Out1 logic function
Selection of the logic operation (OR or AND) for the switching conditions to be evaluated.

Parameter

Info

Lenze setting

C15051/1

C15052/1

SD-Out1 switching condition: STO active

Not evaluated

SD-Out1 switching condition: SS1 active

Not evaluated

SD-Out1 switching condition: SS2 active

Not evaluated

SD-Out1 switching condition: SLS1 active

Not evaluated

SD-Out1 switching condition: SLS2 active

*

Not evaluated

SD-Out1 switching condition: SLS3 active

*

Not evaluated

SD-Out1 switching condition: SLS4 active

*

Not evaluated

SD-Out1 switching condition: SDIpos active

**

Not evaluated

SD-Out1 switching condition: SDIneg active

**

Not evaluated

SD-Out1 switching condition: ES active

Not evaluated

SD-Out1 switching condition: SLI active

***

Not evaluated

SD-Out1 switching condition: OMS

Not evaluated

SD-Out1 switching condition: SOS monitored

Not evaluated

SD-Out1 switching condition: SLS1 monitored

Not evaluated

SD-Out1 switching condition: SLS2 monitored

*

Not evaluated

SD-Out1 switching condition: SLS3 monitored

*

Not evaluated

SD-Out1 switching condition: SLS4 monitored

*

Not evaluated

SD-Out1 switching condition: SDIpos monitored

**

Not evaluated

SD-Out1 switching condition: SDIneg monitored

**

Not evaluated

SD-Out1 switching condition: SSE active

Not evaluated

SD-Out1 switching condition: SD-In1 active

Not evaluated

SD-Out1 switching condition: SD-In2 active

Not evaluated

SD-Out1 switching condition: SD-In3 active

Not evaluated

SD-Out1 switching condition: SD-In4 active

Not evaluated

SD-Out1 switching condition: OMS active

Not evaluated

SD-Out1 switching condition: Error active

Not evaluated

C15055/1

SD-Out1 logic function

OR