C15032 | sd-in free assignment, C15033 | sd-in discrepancy time, C15032/1 – Lenze E94AYAE SM301 User Manual

Page 76: C15033/1, C15032, 5parameter reference

Advertising
background image

5

Parameter reference

5.1

Parameter list | C15032

76

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15032

C15033

Parameter | Name:

C15032 | SD-In free assignment

Data type: UNSIGNED_8

Index: 9543

d

= 2547

h

Assignment of a safety function to a safe input.

• Only possible if the sensor function "Free assignment" is set for the safe input in

C15031

.

Safe inputs

Selection list

Info

0 STO

Safe torque off

1 SS1

Safe stop 1

2 SS2

Safe stop 2

3 SLS1

Safely limited speed 1

4 SLS2

Safely limited speed 2

(from V1.1)

5 SLS3

Safely limited speed 3

(from V1.1)

6 SLS4

Safely limited speed 4

(from V1.1)

7 SDIpos

Safe positive direction

(from V1.3)

8 SDIneg

Safe negative direction

(from V1.3)

9 No response

No (local) safety function assigned.

• Function test and monitoring of the discrepancy time

are active.

• The status of the input is transferred to the control via

the safety bus (if parameterised).

Subcodes

Lenze setting

Info

C15032/1

0: STO

SD-In1 free assignment

C15032/2

0: STO

SD-In2 free assignment

C15032/3

0: STO

SD-In3 free assignment

C15032/4

0: STO

SD-In4 free assignment

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15033 | SD-In discrepancy time

Data type: UNSIGNED_16

Index: 9542

d

= 2546

h

Maximum time for which both channels of a safe input may have non-equivalent states without the safety system

detecting an error.

Safe inputs

Setting range

(min. value | unit | max. value)

0

ms

30000

Subcodes

Lenze setting

Info

C15033/1

10 ms

SD-In1 discrepancy time

C15033/2

10 ms

SD-In2 discrepancy time

C15033/3

10 ms

SD-In3 discrepancy time

C15033/4

10 ms

SD-In4 discrepancy time

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1