1 safe maximum speed (sms), Safe maximum speed (sms), 3safe configuration – Lenze E94AYAE SM301 User Manual

Page 51

Advertising
background image

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

51

3

Safe configuration

3.9

Safety functions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.9.2.1

Safe maximum speed (SMS)

Safe Maximum Speed / SMS
Description

The safety module monitors the adjusted safe maximum speed of the motor.

The function can only be activated by parameter setting.

• See parameter "SMS: Maximum speed Nmax".

• The function must not be parameterised if "No encoder system" is set. The plausibility check

rejects such implausible settings until they have been parameterised correctly.

Function

Parameter

C15320

SMS: Max. speed Nmax

• A value > 0 activates the function, a value = 0 deactivates the function.

C15321

SMS: Reaction (n>Nmax)

• Selection of the function to be executed (

STO

,

SS1

or

SS2

) if monitoring

responds.

C15350

SLS, SMS: Max. response time

• If in the event of an error the speed is still outside the limit values after

the response time has elapsed,

STO

is tripped immediately.

• Detailed information can be found in the chapter "

Error analysis for the

functions SMS and SLS

".

( 53)

Activate

How to activate the function:

• Set the parameter "SMS: Maximum speed Nmax" > 0.

Error behaviour

If the speed exceeds the set maximum speed Nmax, an error message is generated and an error

stop is started with the function set in the parameter "SMS: Reaction (n>Nmax)" (

STO

,

SS1

or

SS2

).

Nmax

t

0

SLS1

Œ

n

SMS

-Nmax

STO/SS1/SS2



Advertising