2 table of attributes, Table of attributes, 5parameter reference – Lenze E94AYAE SM301 User Manual

Page 103

Advertising
background image

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

103

5

Parameter reference

5.2

Table of attributes

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2

Table of attributes

The table of attributes contains information required for communication with the inverter via

parameters.

How to read the table of attributes:

Note!

Safety-relevant parameters with write access can only be transmitted to the safety

module by safe parameter setting with the »Engineer«.

Sending safe data

( 66)

Column

Meaning

Entry

Code

Parameter name

Cxxxxx

Name

Parameter short text (display text)

Text

Index

dec

Index under which the parameter is addressed.

The subindex for array variables corresponds to the

Lenze subcode number.

24575 - Lenze code number

Is only required for access via a bus

system.

hex

5FFF

h

- Lenze code number

Data

DS

Data structure

E

Single variable

(only one parameter element)

A

Array variable

(several parameter elements)

DA

Number of array elements (subcodes)

Number

DT

Data type

BITFIELD_8

1 byte, bit-coded

BITFIELD_16

2 bytes bit-coded

BITFIELD_32

4 bytes bit-coded

BITFIELD_64

8 bytes bit-coded

INTEGER_8

1 byte, with sign

INTEGER_16

2 bytes with sign

INTEGER_32

4 bytes with sign

INTEGER_64

8 bytes with sign

UNSIGNED_8

1 byte without sign

UNSIGNED_16

2 bytes without sign

UNSIGNED_32

4 bytes without sign

UNSIGNED_64

8 bytes without sign

VISIBLE_STRING

ASCII string

Factor

Factor for data transmission via a bus system,

depending on the number of decimal positions

Factor

1 ≡ no decimal positions

10 ≡ 1 decimal position

100 ≡ 2 decimal positions

1000 ≡ 3 decimal positions

Access

R

Read access

Reading permitted

W

Write access

Writing permitted (by safe parameter setting with the »Engineer«)

CINH

Controller inhibit required

Writing is only possible if the controller is inhibited