C15113 | s bus: filter control data, C15113, 5parameter reference – Lenze E94AYAE SM301 User Manual

Page 83

Advertising
background image

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

83

5

Parameter reference

5.1

Parameter list | C15113

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15113

Parameter | Name:

C15113 | S bus: Filter control data

Data type: BITFIELD_32

Index: 9462

d

= 24F6

h

Bit-coded selection of the active bits in the safety bus control data.

Safety bus

Setting range

Lenze setting

0x00000000

0xFFFFFFFF 0x01830BFF (decimal: 25365503)

Value is bit-coded: ( = bit set)

Info

Bit 0  STO

Safe torque off

Bit 1  SS1

Safe stop 1

Bit 2  SS2

Safe stop 2

Bit 3  SLS1

Safely limited speed 1

Bit 4  SLS2

Safely limited speed 2

(from V1.1)

Bit 5  SLS3

Safely limited speed 3

(from V1.1)

Bit 6  SLS4

Safely limited speed 4

(from V1.1)

Bit 7  SDIpos

Safe positive direction

(from V1.3)

Bit 8  SDIneg

Safe negative direction

(from V1.3)

Bit 9  ES

Safe enable switch

Bit 10  Reserved
Bit 11  OMS

Safe operation mode selector

Bit 12  Reserved
Bit 13  Reserved
Bit 14  Reserved
Bit 15  Reserved
Bit 16  PS_AIS

Restart acknowledgement via safety bus

Bit 17  PS_AIE

Error acknowledgement via safety bus

Bit 18  Reserved
Bit 19  Reserved
Bit 20  Reserved
Bit 21  Reserved
Bit 22  Reserved
Bit 23  SSE

Emergency stop function

Bit 24  SD-Out1

Safe output

Bit 25  Reserved
Bit 26  Reserved
Bit 27  Reserved
Bit 28  Reserved
Bit 29  Reserved
Bit 30  Reserved
Bit 31  Reserved

Read access  Write access  CINH  PLC-STOP  No transfer