C15100

C15101

C15111

C15112

Parameter | Name:

C15100 | S bus: Configuration

Data type: UNSIGNED_8

Index: 9475

d

= 2503

h

Configuration of the safe bus system.

Safety bus

Selection list

(Lenze setting printed in bold)

Info

0 No safety bus
1 PROFIsafe / PROFIBUS
2 PROFIsafe / PROFINET

From V1.1

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15101 | Current DIP switch display

Data type: UNSIGNED_16

Index: 9474

d

= 2502

h

Display of the DIP-switch setting (safety address) on the safety module.

Safety address

Display range

(min. value | unit | max. value)

0

1023

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15111 | Safety address

Data type: UNSIGNED_16

Index: 9464

d

= 24F8

h

Safety address in the safety module.

Safety address

Setting range

(min. value | unit | max. value)

Lenze setting

0

65534 0

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15112 | Effective safety address

Data type: UNSIGNED_16

Index: 9463

d

= 24F7

h

Effectively used safety address in the safety module.

Safety address

Display range

(min. value | unit | max. value)

1

65534

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1