Internal error - module switch [0x012f0037, Deactivated sd-in1 = high [0x012f0039, Deactivated sd-in2 = high [0x012f003a – Lenze E94AYAE SM301 User Manual

Page 112: Deactivated sd-in3 = high [0x012f003b, Deactivated sd-in4 = high [0x012f003c, 0x012f0039, 0x012f003a, 0x012f003b, 0x012f003c, 0x012f0037

Advertising
background image

6

Error messages

112

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Internal error - module switch [0x012f0037]

Deactivated SD-In1 = high [0x012f0039]

Deactivated SD-In2 = high [0x012f003a]

Deactivated SD-In3 = high [0x012f003b]

Deactivated SD-In4 = high [0x012f003c]

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

55

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Signal error at module acknowledgement input.

Replace safety module.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

57

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Initialisation/parameterisation error:

Deactivated input in ON state.

Check connection diagram and parameterisation.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

58

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Initialisation/parameterisation error:

Deactivated input in ON state.

Check connection diagram and parameterisation.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

59

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Initialisation/parameterisation error:

Deactivated input in ON state.

Check connection diagram and parameterisation.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

60

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Initialisation/parameterisation error:

Deactivated input in ON state.

Check connection diagram and parameterisation.

Advertising