New parameter set deleted [0x012f00a0, New safe parameter set loaded [0x012f00a1, Different parameter sets [0x012f00a3 – Lenze E94AYAE SM301 User Manual

Page 122: 0x012f00a3, 0x012f00a2, 0x012f00a0, 0x012f00a1, 6error messages

Advertising
background image

6

Error messages

122

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

New parameter set deleted [0x012f00a0]

New safe parameter set loaded [0x012f00a1]

Memory module - parameter set access error [0x012f00a2]

Different parameter sets [0x012f00a3]

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

160

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The parameter set has been deleted via the safe

parameterisaiton in the Engineer.

--

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

161

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

New parameter set has been loaded via the safe

parameterisation in the Engineer or by actuating the

module button at the safety module.

--

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

162

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

An error has been detected when accessing the safe

parameter set in the memory module.

Carry out a general reset. Transfer the safe parameter set

into the safety module.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

163

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Different parameter sets on the memory module and on

the safety module.

Transfer the safe parameter set via the Engineer into the

safety module. Parameter set acceptance from the

memory module using the module button at the safety

module.

Advertising