C15317 | ss1, ss2: ramp - start-offset, C15320 | sms: maximum speed nmax, C15321 | sms: reaction (n>nmax) – Lenze E94AYAE SM301 User Manual

Page 89: C15330 | sls: limited speed nlim, C15317, The tolerance w, C15321, C15330/1, C15330/2, C15330/3

Advertising
background image

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

89

5

Parameter reference

5.1

Parameter list | C15317

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15317

C15320

C15321

C15330

Parameter | Name:

C15317 | SS1, SS2: Ramp - start-offset

Data type: UNSIGNED_8

Index: 9258

d

= 242A

h

From V1.4

Speed offset for the start of ramp monitoring.

Safe stop

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

30 0 %

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15320 | SMS: Maximum speed Nmax

Data type: UNSIGNED_16

Index: 9255

d

= 2427

h

Activation of the SMS function and selection of the maximum speed.

• The setting Nmax = 0 deactivates the function.

Safe maximum speed (SMS)

Setting range

(min. value | unit | max. value)

Lenze setting

0

rpm

16000 1 rpm

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15321 | SMS: Reaction (n>Nmax)

Data type: UNSIGNED_8

Index: 9254

d

= 2426

h

Reaction to exceeding the set maximum speed Nmax.

Safe maximum speed (SMS)

Selection list

(Lenze setting printed in bold)

Info

0 STO

Safe torque off

1 SS1

Safe stop 1

2 SS2

Safe stop 2

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15330 | SLS: Limited speed Nlim

Data type: UNSIGNED_16

Index: 9245

d

= 241D

h

Setting of the safely limited speed.

Safely limited speed (SLS)

Setting range

(min. value | unit | max. value)

0

rpm

16000

Subcodes

Lenze setting

Info

C15330/1

0 rpm

SLS1: Limited speed Nlim1

C15330/2

0 rpm

SLS2: Limited speed Nlim2

(from V1.1)

C15330/3

0 rpm

SLS3: Limited speed Nlim3

(from V1.1)

C15330/4

0 rpm

SLS4: Limited speed Nlim4

(from V1.1)

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Advertising