9 safety functions, 1 safe stop, Safety functions – Lenze E94AYAE SM301 User Manual

Page 41: Safe stop, 3safe configuration

Advertising
background image

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

41

3

Safe configuration

3.9

Safety functions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.9

Safety functions

The parameterisable safety functions are divided into five functional subgroups:

Safe stop

Safe speed limitation

( 50)

Operation mode selection

( 54)

Cascading (CAS)

(from SM301 V1.1)

( 57)

Safe direction

(from SM301 V1.3)

( 58)

3.9.1

Safe stop

General information
The stop functions are divided according to the tripping reason:

• Standard stop (simple stop)

• Tripping by a safe input with the parameterised functions STO, SS1, or SS2*.
• Tripping by activating the bits STO, SS1 or SS2* via the safety bus.
• In special operation (OMS) the standard stop can be avoided by confirming it with the enable

switch (ES).

• Emergency stop

• Tripping by a safe input with the parameterised function SSE.
• Tripping by activating the bit SSE via the safety bus.
• STO or SS1 can be set as the function to be executed via the parameter "SSE: Emergency stop

function".

• In special operation (OMS) the emergency stop cannot be avoided.

• Error stop

• Tripping as response to an error.
• In special operation (OMS) the error stop cannot be avoided.


* Based on EN 61800-5-2 / SOS is speed-monitored

(up to SM301 V1.2)

and

based on the EN 61800-5-2 standard / SOS is position-monitored

(from SM301 V1.3)

Advertising