Stuck at High SD-Out1, channel B [0x012f0082]

Stuck at Low SD-Out1, channel B [0x012f0083]

Stuck at High at SD-In1, channel A [0x012f0090]

Stuck at High at SD-In1, channel B [0x012f0091]

Stuck at High at SD-In2, channel A [0x012f0092]

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

130

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Channel B of output SD-Out1 cannot be deactivated.

Check wiring at the output SD-Out1 for short circuit.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

131

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Channel B of output SD-Out1 cannot be activated.

Check supply voltage and wiring for the safe output.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

144

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Channel A of input SD-In1 cannot be deactivated.

• Check wiring at the safe input for short circuit.

• Check configuration for the safe input.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

145

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Channel B of input SD-In1 cannot be deactivated.

• Check wiring at the safe input for short circuit.

• Check configuration for the safe input.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

146

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Channel A of input SD-In2 cannot be deactivated.

• Check wiring at the safe input for short circuit.

• Check configuration for the safe input.