C15052

Parameter | Name:

C15052 | SD-Out switching condition

Data type: BITFIELD_32

Index: 9523

d

= 2533

h

Bit-coded selection of the conditions for switching the safe output.

Safe output

Setting range
0x00000000

0xFFFFFFFF

Value is bit-coded: ( = bit set)

Info

Bit 0  SOS monitored

Safe operating stop is monitored.

Bit 1  SOS monitored - neg. logic

Safe operating stop is not monitored.

Bit 2  SLS1 monitored

Safely limited speed 1 is monitored.

Bit 3  SLS1 monitored - neg. logic

Safely limited speed 1 is not monitored.

Bit 4  SLS2 monitored

Safely limited speed 2 is monitored

(from V1.1)

Bit 5  SLS2 monitored - neg. logic

Safely limited speed 2 is not monitored.

(from V1.1)

Bit 6  SLS3 monitored

Safely limited speed 3 is monitored

(from V1.1)

Bit 7  SLS3 monitored - neg. logic

Safely limited speed 3 is not monitored

(from V1.1)

Bit 8  SLS4 monitored

Safely limited speed 4 is monitored

(from V1.1)

Bit 9  SLS4 monitored - neg. logic

Safely limited speed 4 is not monitored

(from V1.1)

Bit 10  SDIpos monitored

Safe positive direction is monitored

(from V1.3)

Bit 11  SDIpos observed neg. logic

Safe positive direction is not monitored

(from V1.3)

Bit 12  SDIneg monitored

Safe negative direction is monitored

(from V1.3)

Bit 13  SDIneg observed neg. logic

Safe negative direction is not monitored

(from V1.3)

Bit 14  SSE active

Emergency stop function

Bit 15  SSE active - neg. logic

Emergency stop function

Bit 16  SD-In1 active

Safe inputs

Bit 17  SD-In1 active - neg. logic

Safe inputs

Bit 18  SD-In2 active

Safe inputs

Bit 19  SD-In2 active - neg. logic

Safe inputs

Bit 20  SD-In3 active

Safe inputs

Bit 21  SD-In3 active - neg. logic

Safe inputs

Bit 22  SD-In4 active

Safe inputs

Bit 23  SD-In4 active - neg. logic

Safe inputs

Bit 24  Reserved
Bit 25  Reserved
Bit 26  OMS active

Safe operation mode selector

(from V1.1)

Bit 27  OMS active - neg. logic

Safe operation mode selector

(from V1.1)

Bit 28  Reserved
Bit 29  Reserved
Bit 30  Fault active
Bit 31  Error active - neg. logic

Subcodes

Lenze setting

Info

C15052/1

0x00000000

SD-Out1 switching condition

Read access  Write access  CINH  PLC-STOP  No transfer