C15013 | parameter set creation time, C15014 | time of rtc parameter setting, C15015 | time of sec. parameter setting – Lenze E94AYAE SM301 User Manual

Page 74: C15016 | parameter set version, C15017 | stored module id, 5parameter reference

Advertising
background image

5

Parameter reference

5.1

Parameter list | C15013

74

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15013

C15014

C15015

C15016

C15017

Parameter | Name:

C15013 | Parameter set creation time

Data type: UNSIGNED_64

Index: 9562

d

= 255A

h

Time of parameter set creation.
Display range

(min. value | unit | max. value)

0

2

64

-1

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15014 | Time of RTC parameter setting

Data type: VISIBLE_STRING

Index: 9561

d

= 2559

h

Time of acceptance of the parameter set from the memory module as value of the real-time clock (RTC).

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C15015 | Time of sec. parameter setting

Data type: UNSIGNED_32

Index: 9560

d

= 2558

h

Time of acceptance of the parameter set from the memory module as value of the power-on time meter from the

controller.
Display range

(min. value | unit | max. value)

0

s

4294967295

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15016 | Parameter set version

Data type: UNSIGNED_8

Index: 9559

d

= 2557

h

From V1.1

Display of the parameter set version available in the safety module.
Selection list

(read only)

Info

0 No current parameter set
1 Parameter set V1.0
2 Parameter set V1.1
3 Parameter set V1.2

From V1.2

4 Parameter set V1.3

From V1.3

5 Parameter set V1.4

From V1.4

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15017 | Stored module ID

Data type: UNSIGNED_16

Index: 9558

d

= 2556

h

From V1.2

Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1