C15411 | speed comparison tolerance, C15420 | sin/cos encoder ppr, C15430 | number of resolver pole pairs – Lenze E94AYAE SM301 User Manual

Page 94: C15500 | position encoder system, C15420, C15430, C15500, C15411, 5parameter reference

Advertising
background image

5

Parameter reference

5.1

Parameter list | C15411

94

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15411

C15420

C15430

C15500

Parameter | Name:

C15411 | Speed comparison tolerance

Data type: UNSIGNED_16

Index: 9164

d

= 23CC

h

From V1.3

Parameterisable tolerance of speed comparison in the safety module.

• See note in chapter "

Safe speed measurement and position detection

".

Safe speed measurement and position detection

Setting range

(min. value | unit | max. value)

Lenze setting

0

rpm

16000 20 rpm

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15420 | Sin/cos encoder PPR

Data type: UNSIGNED_16

Index: 9155

d

= 23C3

h

PPR of the sin/cos encoder used.

Safe speed measurement and position detection

Setting range

(min. value | unit | max. value)

Lenze setting

1

16384 1

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15430 | Number of resolver pole pairs

Data type: UNSIGNED_8

Index: 9145

d

= 23B9

h

From V1.3

Number of pole pairs of the resolver used as motor encoder system.

Safe speed measurement and position detection

Setting range

(min. value | unit | max. value)

Lenze setting

1

10 1

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15500 | Position encoder system

Data type: UNSIGNED_8

Index: 9075

d

= 2373

h

From V1.3

Setting of the connected position encoder system.

Safe speed measurement and position detection

Selection list

(Lenze setting printed in bold)

0 No position encoder
1 Analog encoder (sin/cos/TTL)
2 Digital encoder (SSI/bus)

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Advertising