2 safely limited speed (sls), Safely limited speed (sls), Safely limited speed 1 – Lenze E94AYAE SM301 User Manual

Page 52: Safely limited speed 2, Safely limited speed 3, Safely limited speed 4, Safely limited speed 1 (sls1), Function is active, Safely limited speed 2 (sls2), Safely limited speed 3 (sls3)

Advertising
background image

3

Safe configuration

3.9

Safety functions

52

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.9.2.2

Safely limited speed (SLS)

Safely-Limited Speed / SLS
Description

When the value has fallen below the parameterised speed limit Nlim or, at the latest, after the

adjustable braking time has elapsed, the safety module monitors that the set limited speed

Nlim is not exceeded.

• The drive must be braked to the limited speed through the application!

• For operation within the limit values the "SLS1...4 monitored" status is set (

C15000

).

• The status can be assigned to the safe output as a safe speed monitor.

Safe output

( 37)

• The status can also be reported via the safety bus.

• The function must not be parameterised if "No encoder system" is set. The plausibility check

rejects such implausible settings until they have been parameterised correctly.

• The limited speeds SLS2 ... SLS4 are available from SM301 V1.1!

• From SM301 V1.3 you can set both the limited speed and, in addition, the permissible

direction of movement via a parameter.

• When the direction monitoring SDIxxx is combined with the SLSx function, the delay times

must be adapted to each other. The braking time Nlim then starts at the same time as the

SDI delay time.

Function

Function  (monitoring is active before the braking time has elapsed) only from SM301 V1.3

Parameter

C15330/1...4

SLS1...4: Limited speed Nlim

C15331/1...4

SLS1...4: Braking time Nlim

C15332/1...4

SLS1...4: Reaction (n>Nlim)

• Selection of the function to be executed (

STO

,

SS1

or

SS2

) if monitoring

responds.

C15333/1...4

SLS1...4: Perm. direction of movement

C15350

SLS, SMS: Max. response time

• If in the event of an error the speed is still outside the limit values after

the response time has elapsed,

STO

is tripped immediately.

• Detailed information can be found in the chapter "

Error analysis for the

functions SMS and SLS

".

( 53)

Activation

How to activate the function:

• A data telegram with a corresponding content is sent to the controller via the safety bus.

Safety bus ( 59)

• "OFF state" at a safe input which has been assigned to the function by parameter setting.

Safe inputs ( 34)

Error behaviour

If the speed exceeds the set limited speed Nlim in the monitored state, an error message is

generated and an error stop is triggered with the function set in the parameter

"SLS1...4: Reaction (n>Nlim)" (

STO

,

SS1

or

SS2

).



Œ

Ž

t

0

SLS

n

Nlim

STO/SS1/SS2

-Nlim

Œ

t

0

SLS

n

Nlim

SLS observed

-Nlim

0

1

Advertising