C15331 | sls: braking time nlim, C15332 | sls: reaction (n>nlim), C15333 | sls: permissible direction of movement – Lenze E94AYAE SM301 User Manual

Page 90: C15331/1, C15332/1, C15333/1, C15331/2, C15332/2, C15333/2, C15331/3

Advertising
background image

5

Parameter reference

5.1

Parameter list | C15331

90

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15331

C15332

C15333

Parameter | Name:

C15331 | SLS: Braking time Nlim

Data type: UNSIGNED_16

Index: 9244

d

= 241C

h

Safely monitored time for braking the drive below the limited speed set in

C15330

.

Safely limited speed (SLS)

Setting range

(min. value | unit | max. value)

0

ms

30000

Subcodes

Lenze setting

Info

C15331/1

0 ms

SLS1: Braking time Nlim1

C15331/2

0 ms

SLS2: Braking time Nlim2

(from V1.1)

C15331/3

0 ms

SLS3: Braking time Nlim3

(from V1.1)

C15331/4

0 ms

SLS4: Braking time Nlim4

(from V1.1)

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15332 | SLS: Reaction (n>Nlim)

Data type: UNSIGNED_8

Index: 9243

d

= 241B

h

Response carried out in the safety module when the limited speed is exceeded.

Safely limited speed (SLS)

Selection list

Info

0 STO

Safe torque off

1 SS1

Safe stop 1

2 SS2

Safe stop 2

Subcodes

Lenze setting

Info

C15332/1

1: SS1

SLS1: Response (n>Nlim1)

C15332/2

1: SS1

SLS2: Response (n>Nlim2)

(from V1.1)

C15332/3

1: SS1

SLS3: Response (n>Nlim3)

(from V1.1)

C15332/4

1: SS1

SLS4: Response (n>Nlim4)

(from V1.1)

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15333 | SLS: Permissible direction of movement

Data type: UNSIGNED_8

Index: 9242

d

= 241A

h

From V1.3

Permissible direction of movement when monitoring SLS.

Safely limited speed (SLS)

Selection list

0 Both directions enabled
1 Positive direction enabled
2 Negative direction enabled

Subcodes

Lenze setting

Info

C15333/1

0: Both directions enabled

SLS1: Permissible direction of movement

C15333/2

0: Both directions enabled

SLS2: Permissible direction of movement

C15333/3

0: Both directions enabled

SLS3: Permissible direction of movement

C15333/4

0: Both directions enabled

SLS4: Permissible direction of movement

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Advertising