2.5

Parameter setting & configuration

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2.5.2

"LS_SafetyModuleInterface" system block

The LS_SafetyModuleInterface system block is the interface to the safety module in the function

block editor of the »Engineer«.

Outputs

Output

Data type

Value/meaning

SMI_dnState

DINT

Bit coded status information from the safety module

Status information ( 18)

SMI_dnIoState

DINT

Bit coded I/O status information from the safety module

I/O status information ( 19)

SMI_dwControl

DWORD

Bit coded control information from the safety module

Control information ( 20)

SMI_bPowerStageEnable

BOOL

Status signal "Inverter enable"

TRUE Inverter is enabled by the safety module.

SMI_byModuleId

BYTE

ID of the safety module available in the controller

60,BGZ&RQWURO

60,BGQ6WDWH

60,BGQ,R6WDWH

60,BE3RZHU6WDJH(QDEOH

60,BE\0RGXOH,G