C15204 | sli: value of position change, C15205 | sse: emergency stop function, C15300 | restart behaviour – Lenze E94AYAE SM301 User Manual

Page 86: C15305 | ss1, ss2: stopping time, C15205, C15300/1, C15300/2, C15305, 5parameter reference

Advertising
background image

5

Parameter reference

5.1

Parameter list | C15204

86

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15204

C15205

C15300

C15305

Parameter | Name:

C15204 | SLI: Value of position change

Data type: UNSIGNED_32

Index: 9371

d

= 249B

h

From V1.4

Value of the maximum position change while SLI has been active.

Operation mode selection

Display range

(min. value | unit | max. value)

0

Incr.

2147483647

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15205 | SSE: Emergency stop function

Data type: UNSIGNED_8

Index: 9370

d

= 249A

h

Selection of the stop function for emergency stop.

Emergency stop function (SSE)

Selection list

(Lenze setting printed in bold)

Info

0 STO

Safe torque off

1 SS1

Safe stop 1

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15300 | Restart behaviour

Data type: UNSIGNED_8

Index: 9275

d

= 243B

h

Setting of the restart behaviour after deactivation of the STO, SS1, SS2 and SOS standstill function.

Safe stop

Selection list

0 Acknowledged restart
1 Automatic restart

Subcodes

Lenze setting

Info

C15300/1

0: Acknowledged restart

Restart - STO, SS1

C15300/2

0: Acknowledged restart

Restart - SS2, SOS

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15305 | SS1, SS2: Stopping time

Data type: UNSIGNED_16

Index: 9270

d

= 2436

h

Stopping time for the SS1 and SS2 safety functions.

Safe stop

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

30000 0 ms

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Advertising