Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

35

3

Safe configuration

3.7

Safe inputs

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Short overview of "Safe inputs" parameter group:

Sensor type/sensor function
The sensor type and function can be parameterised.

Tip!
Detailed information on sensor inputs, active and passive sensors can be found in the

manual for the safety module.

Parameter

Info

Lenze setting

Value Unit

C15030/1...4

SD-In1...4 sensor type

Input deactivated

C15031/1...4

SD-In1...4 sensor function

Free assignment

C15032/1...4

SD-In1...4 free assignment

STO

C15033/1...4

SD-In1...4 discrepancy time

10 ms

C15034/1...4

SD-In1...4 input delay

0 ms

Note!

If an error (e.g. a discrepancy error) occurs at a safe input to which the "operation mode

selector" sensor function is assigned, the corresponding input is valued as OFF state.

• By this, normal operation is activated

up to SM301 V1.2

.

From SM301 V1.3

the operating mode in the case of LOW level at the safe input can

be parameterised via

C15202

.

• The "Module Error ME" LED blinks,

STO

is not tripped.

• Special operation can only be selected again if the error has been eliminated and

acknowledged.