6error messages – Lenze E94AYAE SM301 User Manual

Page 107

Advertising
background image

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

107

6

Error messages

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x012f00a9

19857577

Module ID unequal effective safety address

Warning

0x012f00a0

19857568

New parameter set deleted

Information

0x012f00a1

19857569

New safety parameter set loaded

Information

0x012f006b

19857515

No encoder system configured

Warning

0x012f00a4

19857572

No safe parameter set for safety module

Warning

0x012f00a8

19857576

Parameter set communicaton error

Information

0x012f00a7

19857575

Parameter set plausibility error

Warning

0x012f0022

19857442

PROFIsafe - communication error

Information

0x012f0026

19857446

PROFIsafe - invalid data

Information

0x012f0047

19857479

PROFIsafe CRC1 error

Information

0x012f0025

19857445

PROFIsafe has left data exchange

Information

0x012f0024

19857444

PROFIsafe passivated

Information

0x012f00c0

19857600

Reference voltage error

Warning

0x012f0048

19857480

Reserved (PROFIsafe standard)

Information

0x012f0049

19857481

Reserved (PROFIsafe standard)

Information

0x012f004a

19857482

Reserved (PROFIsafe standard)

Information

0x012f00d0

19857616

Safe speed invalid

Warning

0x012f0021

19857441

Safety address invalid (0 or FFFFhex)

Warning

0x012f00a5

19857573

Safety parameter set defect

Warning

0x012f0068

19857512

SDIneg: Wrong direction

Warning

0x012f0067

19857511

SDIpos: Wrong direction

Warning

0x012f0059

19857497

Short circuit / cross-circuit - SD-Out

Warning

0x012f006f

19857519

SLI: Safely limited increment exceeded

Warning

0x012f0066

19857510

SLS/SMS: Error stop not executed

Warning

0x012f0062

19857506

SLS1: Nlim1 exceeded

Warning

0x012f0063

19857507

SLS2: Nlim2 exceeded

Warning

0x012f0064

19857508

SLS3: Nlim3 exceeded

Warning

0x012f0065

19857509

SLS4: Nlim4 exceeded

Warning

0x012f0069

19857513

SMS: Nmax exceeded

Warning

0x012f006a

19857514

SOS: Tolerance limit exceeded

Warning

0x012f006e

19857518

SS1/SS2: Speed ramp exceeded

Warning

0x012f0061

19857505

SS1/SS2: Stopping time exceeded

Warning

0x012f00d1

19857617

SSM: Encoder error

Warning

0x012f00d3

19857619

SSM: Error - standard device data

Warning

0x012f00d2

19857618

SSM: Resolver error

Warning

0x012f00d4

19857620

SSM: Speed comparison error

Warning

0x012f00d5

19857621

SSM: Synchronisation error

Warning

0x012f00d6

19857622

SSM: Wrong PDO version

Warning

0x012f0090

19857552

Stuck at High at SD-In1, channel A

Warning

0x012f0091

19857553

Stuck at High at SD-In1, channel B

Warning

0x012f0092

19857554

Stuck at High at SD-In2, channel A

Warning

0x012f0093

19857555

Stuck at High at SD-In2, channel B

Warning

0x012f0094

19857556

Stuck at High at SD-In3, channel A

Warning

0x012f0095

19857557

Stuck at High at SD-In3, channel B

Warning

0x012f0096

19857558

Stuck at High at SD-In4, channel A

Warning

0x012f0097

19857559

Stuck at High at SD-In4, channel B

Warning

0x012f0080

19857536

Stuck at High SD-Out1, channel A

Warning

0x012f0082

19857538

Stuck at High SD-Out1, channel B

Warning

0x012f0081

19857537

Stuck at Low SD-Out1, channel A

Warning

0x012f0083

19857539

Stuck at Low SD-Out1, channel B

Warning

0x012f0011

19857425

Synchronisation error - standard device

Information

0x012f005e

19857502

Test pulse error - internal disconnecting path

Warning

hex

dec

Error message

Response (Lenze setting)

Advertising