C15402 | actual speed - n_safe, C15405 | internal actual speed value, C15409 | motor mounting direction – Lenze E94AYAE SM301 User Manual

Page 93: C15410 | response time of encoder monitoring, C15409, D via, C15410, 5parameter reference

Advertising
background image

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

93

5

Parameter reference

5.1

Parameter list | C15402

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15402

C15405

C15409

C15410

Parameter | Name:

C15402 | Actual speed - n_safe

Data type: INTEGER_16

Index: 9173

d

= 23D5

h

Display of the current speed calculated by the safety module.

Safe speed measurement and position detection

Display range

(min. value | unit | max. value)

-16000

rpm

16000

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15405 | Internal actual speed value

Data type: INTEGER_16

Index: 9170

d

= 23D2

h

From V1.4

Internal actual speed values of the SM301.

Safe speed measurement and position detection

Display range

(min. value | unit | max. value)

-16000

rpm

16000

Subcodes

Info

C15405/1

Internal actual speed value nSM determined from the

motor position.

C15405/2

Internal actual speed value nGG determined from the

position data of the standard device.

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15409 | Motor mounting direction

Data type: UNSIGNED_8

Index: 9166

d

= 23CE

h

From V1.4

Setting of the motor mounting direction.

Safe speed measurement and position detection

Selection list

(Lenze setting printed in bold)

0 Motor rotating CW
1 Motor rotating CCW

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15410 | Response time of encoder monitoring

Data type: UNSIGNED_8

Index: 9165

d

= 23CD

h

From V1.2

Response time of encoder monitoring.

Safe speed measurement and position detection

Selection list

(Lenze setting printed in bold)

0 12ms

10 50ms
20 100 ms

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1