3
Safe configuration
3.10
Safety bus
64
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
25 SD-In2
1
Sensor at I2A and I2B: Channels A and B are in ON state.
26 SD-In3
1
Sensor at I3A and I3B: Channels A and B are in ON state.
27 SD-In4
1
Sensor at I4A and I4B: Channels A and B are in ON state.
29 OMS active
*
1
The OMS function is active: Special operation.
• In contrast to bit 11 (OMS), this bit remains set until the special
operation is cancelled and the change-over to normal operation
has taken place via the stop function.
0
The OMS function is not active: Normal operation.
31 Fault active
1
Error status is active (fault or warning).
Bit
Name
Value
Meaning
* From SM301 V1.1 ** From SM301 V1.3 *** From SM301 V1.4
Unlisted bits are reserved for future extensions and must be transmitted with "0"!