Error messages

126

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Note: The use of the safety module in version 1.4 with parameter set version 1.4 and support of the resolver as motor

encoder requires standard devices of the 9400 product series from nameplate inscription:

SSM: Standard device data error [0x012f00d3]

SSM: Speed comparison error [0x012f00d4]

SSM: Synchronisation error [0x012f00d5]

SSM: Wrong PDO version [0x012f00d6]

Product series

Type designation

From hardware version

From software version

Servo Drives 9400

E94AxHExxxx

VA

08.xx

Servo Drives 9400

E94AxPExxxx

2A

02.xx

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

211

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Error in safe speed monitoring. The data transferred by

the standard device is faulty.

Please contact Lenze.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

212

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The difference between the speed calculated internally

and the speed values of the standard device exceeds the

parameterised limit.

• Check configuration of the encoder system/s and

gearbox factor.

• Check tolerance value for the speed comparison (from

SM301 V1.3).

• Set code C00100 in the 9400 to "16" if a digital

position encoder is used.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

213

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Error in safe speed monitoring: Faulty synchronisation

between the standard device and the safety module.

Please contact Lenze.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

214

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Error in safe speed monitoring: PDO version of data

protocol is incompatible.

The SM301 V1.3 parameter set format requires

operating system version 07.00.xx.xx or higher in the

standard device.

Advertising