Safe parameter transfer

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4

Safe parameter transfer

The functions for a safe parameter transfer are

available in the Safe transfer dialog box.
The Safe transfer dialog box is opened via the Safe

transfer button on the Safe configuration tab for the

SM301 safety module.

By clicking the More >> button in the Safe transfer

dialog box, the functions for password

management and general reset are displayed in

addition.
Clicking the button now labelled with << Reduce

hides these functions again.

Note!

To execute the functions for a safe parameter transfer, you have to enter a device

password!
When the memory module is used for the first time together with the safety module, the

required password file for the safe parameter transfer is not yet available in the memory

module and the error message "Reading of the password file failed" is displayed. In this

case a general reset of the device is required!
With a general reset, the safe parameter set is deleted in the memory module and in the

safety module and the required password file is created in the memory module. After

this, the safety module must be re-parameterised.

General reset of the device

( 69)