C15000

Parameter | Name:

C15000 | Status of safety functions

Data type: BITFIELD_32

Index: 9575

d

= 2567

h

Bit-coded status word of the safety functions
Display range
0x00000000

0xFFFFFFFF

Value is bit-coded:

Info

Bit 0 STO is active

Safe torque off

Bit 1 SS1 active

Safe stop 1

Bit 2 SS2 active

Safe stop 2

Bit 3 SLS1 active

Safely limited speed 1

Bit 4 SLS2 active

Safely limited speed 2

(from V1.1)

Bit 5 SLS3 active

Safely limited speed 3

(from V1.1)

Bit 6 SLS4 active

Safely limited speed 4

(from V1.1)

Bit 7 SDIpos active

Safe positive direction

(from V1.3)

Bit 8 SDIneg active

Safe negative direction

(from V1.3)

Bit 9 ES active

Safe enable switch

Bit 10 SLI active

Safely limited increment

(from V1.4)

Bit 11 OMS

Safe operation mode selector

Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Bit 16 SOS monitored

Safe operating stop is monitored.

Bit 17 SLS1 monitored

Safely limited speed 1 is monitored.

Bit 18 SLS2 monitored

Safely limited speed 2 is monitored

(from V1.1)

Bit 19 SLS3 monitored

Safely limited speed 3 is monitored

(from V1.1)

Bit 20 SLS4 monitored

Safely limited speed 4 is monitored

(from V1.1)

Bit 21 SDIpos monitored

Safe positive direction is monitored

(from V1.3)

Bit 22 SDIneg monitored

Safe negative direction is monitored

(from V1.3)

Bit 23 SSE active

Emergency stop function

Bit 24 SD-In1 active

Safe inputs

Bit 25 SD-In2 active

Safe inputs

Bit 26 SD-In3 active

Safe inputs

Bit 27 SD-In4 active

Safe inputs

Bit 28 Reserved
Bit 29 OMS active

Safe operation mode selector

(from V1.1)

Bit 30 Reserved
Bit 31 Fault active

Read access  Write access  CINH  PLC-STOP  No transfer