F_crc_length error [0x012f0045, F parameter version is incorrect [0x012f0046, Profisafe crc1 error [0x012f0047 – Lenze E94AYAE SM301 User Manual

Page 114: Reserved (profisafe standard) [0x012f0048, Reserved (profisafe standard) [0x012f0049, 0x012f0045, 0x012f0046, 0x012f0047, 0x012f0048, 0x012f0049

Advertising
background image

6

Error messages

114

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

F_CRC_Length error [0x012f0045]

F parameter version is incorrect [0x012f0046]

PROFIsafe CRC1 error [0x012f0047]

Reserved (PROFIsafe standard) [0x012f0048]

Reserved (PROFIsafe standard) [0x012f0049]

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

69

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The data length of the F_CRC of the control system is

faulty.

Check the safety parameters in the control system.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

70

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The F parameter version is incorrect and not supported

by the safety module.

Select a permissible F parameter version in the control

system.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

71

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

PROFIsafe-CRC1 error. Current F parameter CRC is faulty.

• Check F parameter CRC (CRC1) in the control system.

• Check GSD file.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

72

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

--

--

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

73

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

--

--

Advertising