C15055 | sd-out logic function, C15060 | output image, 5parameter reference – Lenze E94AYAE SM301 User Manual

Page 81

Advertising
background image

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

81

5

Parameter reference

5.1

Parameter list | C15055

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15055

C15060

Parameter | Name:

C15055 | SD-Out logic function

Data type: UNSIGNED_8

Index: 9520

d

= 2530

h

Selection of the logic operation for the switching conditions to be evaluated.

Safe output

Selection list

0 OR
1 AND

Subcodes

Lenze setting

Info

C15055/1

0: OR

SD-Out1 logic function

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15060 | Output image

Data type: BITFIELD_16

Index: 9515

d

= 252B

h

Output image of the feedbacks from the safety module, displayed according to channels.
Display range
0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 SD-Out1 channel A

Safe output

Bit 1 SD-Out1 channel B

Safe output

Bit 2 Reserved
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved

Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved

Read access  Write access  CINH  PLC-STOP  No transfer