C15003 | command status, C15010 | parameter set status, C15011 | parameter crc – Lenze E94AYAE SM301 User Manual

Page 73: 5parameter reference

Advertising
background image

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

73

5

Parameter reference

5.1

Parameter list | C15003

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15003

C15010

C15011

Parameter | Name:

C15003 | Command status

Data type: UNSIGNED_16

Index: 9572

d

= 2564

h

Status of the current command.

• The command is repeated in the high byte.

• In the low byte the status is displayed:

0x00: No command

0x01: Command executed

0x02: Password invalid

0x03: Command in process

0x04: Command not known

0x05: Command error

Display range

(min. value | unit | max. value)

0

2309

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15010 | Parameter set status

Data type: UNSIGNED_8

Index: 9565

d

= 255D

h

Status of the parameter set.
Selection list

(read only)

0 No parameter set
1 Parameter set valid
2 Read error - memory module
3 Unequal parameter set
4 CRC error
5 Version error
6 Format error
7 Plausibility error
8 Assignment error
9 Local read error

10 GG communication error

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15011 | Parameter CRC

Data type: UNSIGNED_32

Index: 9564

d

= 255C

h

Parameter checksum (CRC = Cyclic Redundancy Code).
Display range

(min. value | unit | max. value)

0

4294967295

Subcodes

Info

C15011/1

CRC safety module

C15011/2

CRC memory module

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1