Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

85

5

Parameter reference

5.1

Parameter list | C15200

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15200

C15201

C15202

C15203

Parameter | Name:

C15200 | OMS: Stop function

Data type: UNSIGNED_8

Index: 9375

d

= 249F

h

Selection of the stop function during special operation.

Operation mode selection

Selection list

(Lenze setting printed in bold)

Info

0 STO

Safe torque off

1 SS1

Safe stop 1

2 SS2

Safe stop 2

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15201 | OMS: Motion function

Data type: UNSIGNED_8

Index: 9374

d

= 249E

h

Selection of the motion function during special operation.

Operation mode selection

Selection list

(Lenze setting printed in bold)

Info

3 SLS1

Safely limited speed 1

4 SLS2

Safely limited speed 2

(from V1.1)

5 SLS3

Safely limited speed 3

(from V1.1)

6 SLS4

Safely limited speed 4

(from V1.1)

11 Free traversing

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15202 | OMS: Function at LOW level

Data type: UNSIGNED_8

Index: 9373

d

= 249D

h

From V1.3

Danger!

If the operation mode selector is implemented via a safe input, the operating mode for the LOW level must be

selected carefully. According to the closed-circuit principle, there must not arise any additional danger from normal

or special operation in the corresponding application.

For detailed information, please see the manual for the safety module.

Safe operation mode selector

Selection list

(Lenze setting printed in bold)

Info

0 Normal operation

Operation mode selection

1 Special operation

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15203 | SLI: Safely limited increment

Data type: UNSIGNED_32

Index: 9372

d

= 249C

h

From V1.4

Number of increments for safely limited increment.

• Value "0" deactivates the SLI function.

Operation mode selection

Setting range

(min. value | unit | max. value)

Lenze setting

0

Incr.

2147483647 1 inc.

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1