Safe configuration

3.10

Safety bus

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

PROFIsafe message
One bit of the PROFIsafe data is always used to control specific safety functions.

• The structure of the PROFIsafe data is described in the PROFIsafe profile.
• The length of the PROFIsafe message in the SM301 is 8 bytes (fix).

• In the following subchapters, the meaning of the PROFIsafe process data is separately described

for PROFIsafe output data and PROFIsafe input data.

Tip!
Detailed information on the PROFIsafe message can be found in the manual for the safety

module and in the PROFIBUS or PROFINET communication manual (

PROFINET is supported

from SM301 V1.1

).

PROFIsafe message - V1 mode

Bit offset

Byte offset

7

6

5

4

3

2

1

0

0

PROFIsafe process data

(PROFIsafe output data/PROFIsafe input data)

1
2
3
4

Control byte or status byte

5

Consecutive number

6

CRC2

(Signature originating from PROFIsafe process data and PROFIsafe parameters)

7

PROFIsafe message - V2 mode

(From SM301 V1.1)

Bit offset

Byte offset

7

6

5

4

3

2

1

0

0

PROFIsafe process data

(PROFIsafe output data/PROFIsafe input data)

1
2
3
4

Control byte or status byte

5

CRC2

(Signature originating from PROFIsafe process data, PROFIsafe parameters

and the consecutive number)

6
7