5 general reset of the device, General reset of the device, 4safe parameter transfer – Lenze E94AYAE SM301 User Manual

Page 69

Advertising
background image

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

69

4

Safe parameter transfer

4.5

General reset of the device

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.5

General reset of the device

A general reset is, among other things, required for initialising the memory module if the controller

(with the memory module) is used together with an SM301 safety module for the first time.

How to execute a general reset of the device:

1. Unless there is an online connection, establish an online connection to the device.
2. Go to the advanced Safe transfer dialog box and click General reset.

• The Standard password entry dialog box is displayed.

3. Enter the standard password and confirm with OK.

• The standard password can be found in the manual for the safety module.

The general reset is executed and then a status message displays whether the action could

be carried out successfully.

4. Confirm the status message with OK.

Note!

This function serves to reset safety data in the memory module.

• The safe parameter set in the memory module and in the safety module is deleted.
• The password file required for the safe parameter transfer is re-created in the memory

module. By this the individual device password defined before is reset to the standard

password.

• Afterwards the safety module must be re-parameterised.
• The module ID stored in the safety module remains available.