1 priorisation, Priorisation, 3safe configuration – Lenze E94AYAE SM301 User Manual

Page 42

Advertising
background image

3

Safe configuration

3.9

Safety functions

42

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Short overview of "Safety functions Safe stop" parameter group:

3.9.1.1

Priorisation

Stop functions with priority influence the process of already started subordinated functions.

1.

Safe torque off (STO)

• The STO function has the highest priority and thus takes priority over all other functions.

Functions already started (e.g. SS1 or SS2) are cancelled and the drive is switched off.

2.

Safe stop 1 (SS1)

• The SS1 function has priority over SS2. Taking the stopping time set for SS1 and SS2 and for

the SS1 mode

(from SM301 V1.3)

into consideration, the drive is switched to torque-free

operation.

3. Monitoring functions

• The monitoring functions have the same priorities. They can also be executed parallel to the

stop function.

Parameter

Info

Lenze setting

Value Unit

C15205

SSE: Emergency stop function

STO

C15300/1

Restart behaviour - STO, SS1

Acknowledged restart

C15300/2

Restart behaviour - SS2, SOS

Acknowledged restart

C15305

SS1, SS2: Stopping time

0 ms

C15306

SS1 mode

*

STO after stopping time

C15307

SS1: STO delay after n=0

*

0 ms

C15308

SS2 mode

*

SOS after stopping time

C15310

Speed window (n=0)

0 rpm

C15311

SOS: Tolerance margin (delta p=0)

*

0 Incr.

C15315

SS1, SS2: Ramp monitoring

**

Ramp monitoring activated

C15316

SS1, SS2: Ramp - S-ramp time

**

0 %

C15317

SS1, SS2: Ramp - start-offset

**

0 %

* From SM301 V1.3 ** From SM301 V1.4

Advertising