_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Stuck at High at SD-In2, channel B [0x012f0093]

Stuck at High at SD-In3, channel A [0x012f0094]

Stuck at High at SD-In3, channel B [0x012f0095]

Stuck at High at SD-In4, channel A [0x012f0096]

Stuck at High at SD-In4, channel B [0x012f0097]

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

147

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Channel B of input SD-In2 cannot be deactivated.

• Check wiring at the safe input for short circuit.

• Check configuration for the safe input.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

148

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Channel A of input SD-In3 cannot be deactivated.

• Check wiring at the safe input for short circuit.

• Check configuration for the safe input.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

149

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Channel B of input SD-In3 cannot be deactivated.

• Check wiring at the safe input for short circuit.

• Check configuration for the safe input.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

150

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Channel A of input SD-In4 cannot be deactivated.

• Check wiring at the safe input for short circuit.

• Check configuration for the safe input.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

151

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Channel B of input SD-In4 cannot be deactivated.

• Check wiring at the safe input for short circuit.

• Check configuration for the safe input.