C15306 | ss1 mode, C15307 | ss1: sto delay after n=0, C15308 | ss2 mode – Lenze E94AYAE SM301 User Manual

Page 87: C15310 | speed window (n=0), C15306, C15307, C15308, C15310, C15320, 5parameter reference

Advertising
background image

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

87

5

Parameter reference

5.1

Parameter list | C15306

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15306

C15307

C15308

C15310

Parameter | Name:

C15306 | SS1 mode

Data type: UNSIGNED_8

Index: 9269

d

= 2435

h

From V1.3

Selection whether STO is already activated after reaching n=0 when SS1 is executed or only after the parameterised

stopping time.

Safe stop 1 (SS1)

Selection list

(Lenze setting printed in bold)

0 STO after stopping time
1 STO when n=0

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15307 | SS1: STO delay after n=0

Data type: UNSIGNED_16

Index: 9268

d

= 2434

h

From V1.3

Delay time after detection of n=0 until activation of STO.

• Only relevant if "SS1 mode" = "STO with n=0" and operation with encoder system.

Safe stop 1 (SS1)

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

30000 0 ms

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15308 | SS2 mode

Data type: UNSIGNED_8

Index: 9267

d

= 2433

h

From V1.3

Selection whether SOS is already activated after reaching n=0 when SS2 is executed or only after the parameterised

stopping time.

Safe stop 2 (SS2)

Selection list

(Lenze setting printed in bold)

0 SOS after stopping time
1 SOS when n=0

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1

Parameter | Name:

C15310 | Speed window (n=0)

Data type: UNSIGNED_16

Index: 9265

d

= 2431

h

Tolerance window for zero speed.

Safe stop

Setting range

(min. value | unit | max. value)

Lenze setting

0

rpm

16000 0 rpm

Read access  Write access  CINH  PLC-STOP  No transfer Scaling factor: 1