Load initial configuration values chapter 7 – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 102

Advertising
background image

Enter Your Values Here

Load Initial Configuration Values

Chapter 7

7-16

Worksheet 7ĆG (continued)
Clamp Open Configuration Blocks (FOC, SOC, TOC, and OSC)

For these Parameters (footnote = units)

Word FOC N43 FOC Value SOC N43 SOC Value TOC N43 TOC Value OSC N43 OSC Value

Minimum ERC Percentage - Velocity

8

05

301

1000

361

1000

421

1000

481

1000

Minimum ERC Percentage - Pressure

8

06

302

1000

362

1000

422

1000

482

1000

Profile Watchdog Timer Preset

1

08

304

0

364

0

424

0

484

0

#1 Selected Valve SetĆOutput During Profile

4

09

305

*

365

*

425

*

485

*

#2 Selected Valve SetĆOutput During Profile

4

10

306

*

366

*

426

*

486

*

#3 Selected Valve SetĆOutput During Profile

4

11

307

*

367

*

427

*

487

*

#4 Selected Valve SetĆOutput During Profile

4

12

308

*

368

*

428

*

488

*

Output #1 Accel Ramp Rate During Profile

5

17

313

0

373

0

433

0

493

0

Output #2 Accel Ramp Rate During Profile

5

18

314

0

374

0

434

0

494

0

Output #3 Accel Ramp Rate During Profile

5

19

315

0

375

0

435

0

495

0

Output #4 Accel Ramp Rate During Profile

5

20

316

0

376

0

436

0

496

0

Output #1 Decel Ramp Rate During Profile

5

25

321

0

381

0

441

0

501

0

Output #2 Decel Ramp Rate During Profile

5

26

322

0

382

0

442

0

502

0

Output #3 Decel Ramp Rate During Profile

5

27

323

0

383

0

443

0

503

0

Output #4 Decel Ramp Rate During Profile

5

28

324

0

384

0

444

0

504

0

#1 EndĆofĆprofile SetĆoutput Value

4

33

329

*

389

*

449

*

509

*

#2 EndĆofĆprofile SetĆoutput Value

4

34

330

*

390

*

450

*

510

*

#3 EndĆofĆprofile SetĆoutput Value

4

35

331

*

391

*

451

*

511

*

#4 EndĆofĆprofile SetĆoutput Value

4

36

332

*

392

*

452

*

512

*

Pressure Minimum Control Limit

3

41

337

0

397

0

457

0

517

0

Pressure Maximum Control Limit

3

42

338

Syst Press 398

Syst Press 458

Syst Press 518

Syst Press

Selected Pressure Valve Output for Min

4

43

339

*

399

*

459

*

519

*

Selected Pressure Valve Output for Max

4

44

340

*

400

*

460

*

520

*

Velocity Minimum Control Limit

2

45

341

0

401

0

461

0

521

0

Velocity Maximum Control Limit

2

46

342

per OEM * 402

per OEM * 462

per OEM * 522

per OEM *

Selected Velocity Valve Output for Min

4

47

343

*

403

*

463

*

523

*

Selected Velocity Valve Output for Max

4

48

344

*

404

*

464

*

524

*

Proportional Gain for Pressure Control

(none)

49

345

100

405

100

465

100

525

100

Integral Gain for Pressure Control

6

50

346

400

406

400

466

400

526

400

Derivative Gain for Pressure Control

7

51

347

0

407

0

467

0

527

0

Proportional Gain for Velocity Control

6

52

348

200

408

200

468

200

528

200

Feed Forward Gain for Velocity Control

(none)

53

349

0

409

0

469

0

529

0

Profile High Pressure Alarm Setpoint

3

57

353

0

413

0

473

0

533

0

1

Time

2

Velocity along Axis

3

Pressure

4

Percent Signal Output

00.00 to 99.99 Seconds

00.00 to 99.99 Inches per Second

0000 to 9999 PSI

00.00 to 99.99

000.0 to 999.9 Millimeters per Sec

000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999

00.00 to 99.99 Minutes

00.00 to 99.99 Minutes

00.00 to 99.99

00.00 to 99.99 Seconds

* Important: Refer to the appropriate section later in this chapter for information on this parameter