Record Your SWTL Configuration Values Here

Configure the QDC Module's I/O

Chapter 3

3-15

Configure the QDC module for SWTL alarms as follows:

1.

Determine these SWTL values for ram (screw), clamp, and/or ejector
travel with respect to the range of physical travel.

SWTL deadband
Maximum SWTL
Minimum SWTL

2.

Record non-zero SWTL values on Worksheet 3-F. Zero values
disable the corresponding SWTLs.

ATTENTION: Leaving your SWTL settings at zero (MCC13,
14, 27, 28, 41, 42) inhibits the QDC module from performing
this safety function.

Worksheet 3ĆF

SWTL Configuration Values

Control Word

ProĆSet 600 Addr. Value

Description

MCC13

N40:9

Screw Minimum SWTL

1

MCC14

N40:10

Screw Maximum SWTL

1

MCC15

N40:11

10

Screw SWTL Deadband

2

MCC27

N40:23

Clamp Minimum SWTL

1

MCC28

N40:24

Clamp Maximum SWTL

1

MCC29

N40:25

10

Clamp SWTL Deadband

2

MCC41

N40:37

Ejector Minimum SWTL

1

MCC42

N40:38

Ejector Maximum SWTL

1

MCC43

N40:39

10

Ejector SWTL Deadband

2

1

Incremental distance measured from zero

2

Incremental distance measured as noted

00.00 to 99.99 Inches

00.00 to 99.99 Inches

000.0 to 999.9 Millimeters

000.0 to 999.9 Millimeters

You may now download your adjusted values to the QDC module using
the MCC download procedure presented earlier in this chapter.